Corrugated Tubing

Introduction

Corrugated tubing (also called wire loom tubing or convoluted tubing) is a flexible conduit used to protect and route wire harnesses in automotive, industrial, and automation applications.

Its corrugated wall structure delivers high flexibility combined with crush resistance. Choose from Nylon (PA) or PP polypropylene for standard environments, or opt for galvanized steel flexible conduit when high-temperature, chemical exposure, or EMI shielding is required.

Good Gi corrugated tubing is manufactured in Taiwan with a full range of tooling sizes. Custom cut-to-length, split, and packaging services are available. Products are manufactured in accordance with UL 1696 standards, are RoHS and REACH compliant, and automotive grades meet FMVSS 302 horizontal burn requirements.

Photo Product Name Material Operating Temp. Flame Rating
Polyamide(Nylon) Corrugated Tubing GPA Polyamide(Nylon) Corrugated Tubing
GPA
Polyamide 6 (PA6) / Nylon 6 -10℃~120℃ VW-1
Polyamide(Nylon) Convoluted Tubing GPA-X Polyamide(Nylon) Convoluted Tubing
GPA-X
Polyamide Nylon6 -10℃~120℃ VW-1
Polypropylene Corrugated Tubing GR Polypropylene Corrugated Tubing
GR
Polypropylene -40℃~125℃ 94V-0
Acid and Alkali Resistant Polypropylene Corrugated Tubing GRX-AA Acid and Alkali Resistant Polypropylene Corrugated Tubing
GRX-AA
Acid & Alkali Resistant Plastic -40℃~125℃ 94V-0
Polypropylene Corrugated Conduits GR-X Polypropylene Corrugated Conduits
GR-X
Polypropylene -40℃~125℃ 94V-0
Photo Product Name Material Type Outer layer
1.8mm Stainless Steel Fiber Optic Conduit SSF-18 1.8mm Stainless Steel Fiber Optic Conduit
SSF-18
SUS304 Stainless Steel Squarelock (Flexible) -
Doublelocked Galvanized Steel Flexible Conduit T02 Doublelocked Galvanized Steel Flexible Conduit
T02
Galvanized steel strip Doublelocked -
Squarelocked Galvanized Steel Flexible Conduit T01 Squarelocked Galvanized Steel Flexible Conduit
T01
Galvanized steel strip Square-Locked -
Waterproof Liquid Tight Flexible Conduit TP01 Waterproof Liquid Tight Flexible Conduit
TP01
Galvanized steel strip Doublelocked PVC
Photo Product Name Flame Rating Material Operating Temp.
Acid-alkali Resistant Polypropylene Cable Ties 1ZPP01TST Acid-alkali Resistant Polypropylene Cable Ties
1ZPP01TST
UL94V-2 Polypropylene -40~85℃
Acid-alkali Resistant Cable Tie Mount 1ZPPKHC Acid-alkali Resistant Cable Tie Mount
1ZPPKHC
UL94V-2 Polypropylene -
Photo Product Name Product Usage
Multi-axis Mounting Bracket (for 3D Cable Chains) GRGTFW Multi-axis Mounting Bracket (for 3D Cable Chains)
GRGTFW
Secures the cable carrier end and guides cables, improving stability and durability.
Multi-axis Side-opening Cable Carrier GRGTL Multi-axis Side-opening Cable Carrier
GRGTL
Side-open design enables easy installation and maintenance, delivering flexible and reliable cable protection.
Industrial Flame-Retardant Waterproof Junction Box - Bolt-Fix Type WBX Industrial Flame-Retardant Waterproof Junction Box - Bolt-Fix Type
WBX
Engineering-grade injection-moulded waterproof enclosure, IP67 rated, PC/ABS/flame-retardant material options, bolt-fix sealed, UL/RoHS/CE certified.

PP Corrugated Tubing Manufacturing Process — EV Orange Grade

A full production walkthrough of Good Gi PP polypropylene corrugated tubing — from raw material extrusion to finished tube — so you can see Taiwan-made quality standards firsthand.

Source: Good Gi Co., Ltd. Official YouTube Channel

Key Features

  • Built to International Standards: Nylon (PA) grades are manufactured in accordance with UL 1696 mechanical protection tubing standards; PP grades use resin rated to UL 94 V-0 and meet FMVSS 302 horizontal burn requirements. All grades are RoHS and REACH compliant. Test reports available on request.

  • Impact & Heat Resistance: Plastic grades rated −40 °C to 125 °C; metal flexible conduit handles extreme heat and electromagnetic interference.

  • High Flexibility: Corrugated walls allow free bending in any direction — ideal for complex routing paths and tight installation spaces.

  • Multiple Material Options: Nylon (PA), PP polypropylene, chemical-resistant grades, and galvanized metal flexible conduit — one supplier for every operating environment.

  • Taiwan-Manufactured: In-house tooling and quality control ensure consistent lead times and support for high-volume custom orders.

  • Complete Processing Services: Cut-to-length, longitudinal slitting, and custom packaging reduce downstream prep work and total procurement cost.

Application Areas

  • Semiconductor & Electronics Equipment: Protects precision harnesses in cleanrooms and high-accuracy machinery. RoHS compliance is mandatory; Nylon (PA) corrugated tubing, manufactured to UL 1696 mechanical protection tubing standards, is the primary choice.

  • Energy & Power Equipment: Used in power control panels, new-energy systems, and power unit wiring — where heat resistance and chemical durability are critical. PP or metal conduit selected by environment.

  • Automation & Machine Tools: Shields internal wire harnesses against repeated flexing and elevated temperatures, extending harness service life.

  • Automotive Wiring & Electrical Insulation: Grades meeting FMVSS 302 horizontal burn requirements are widely used in engine compartment, door, and dashboard harness protection.

  • Construction & Outdoor Wiring: High protection ratings suit underground conduit runs and outdoor exposed installations — dust-proof, moisture-resistant, and weather-durable.

  • Chemical Industry & Harsh Environments: Chemical-resistant PP grades withstand acid and alkali exposure, keeping precision circuits stable in aggressive industrial environments.

Recommended Corrugated Tube Cutting Machines

Frequently Asked Questions

Q: Nylon (PA) vs. PP Corrugated Tubing — Which Should I Choose?

A: Start with the environment, then the mechanical load. Choose Nylon/PA (GPA) where abrasion resistance, impact strength, and mechanical durability matter — robotic arms, cable chains with repeated travel, and harnesses that flex constantly inside equipment. Rated −10 °C to 120 °C and manufactured to UL 1696 mechanical protection tubing standards. Choose PP (GR) where chemical resistance, low-temperature tolerance, or cost control lead — chemical plants, outdoor low-temperature runs, and automotive harnesses. Rated −40 °C to 125 °C and meets FMVSS 302 horizontal burn requirements. Quick rule: heavy movement and abrasion → PA; chemicals and cold → PP. For a full side-by-side comparison, see Nylon (PA) vs. PP Corrugated Tubing — Material Comparison Guide.

Q: How Do I Select the Right Corrugated Tube Size?

A: The basic rule: the wire harness OD should not exceed 60–70% of the tube's inner diameter. Divide the harness OD by 0.65 to get the minimum recommended ID (example: 12 mm harness OD → choose ID ≥ 19 mm), then pick the nearest standard size from the supplier's catalog. If you anticipate adding cables later, go one size up. For a complete sizing walkthrough, see How to Select the Right Corrugated Tube Size and Specifications.

Q: What Do UL, RoHS, and REACH Mean for Corrugated Tubing Procurement?

A: These are separate systems covering different markets. UL 1696 is the mechanical protection tubing (MPT) standard, covering support, routing, and mechanical protection of wires and cables — the reference point for North American equipment wiring. UL 94 V-0 is a plastics flammability rating requiring self-extinguishing within 10 seconds. FMVSS 302 is the US automotive horizontal burn requirement. RoHS restricts 10 hazardous substances including lead, mercury, and cadmium; REACH controls substances of very high concern (SVHC) — both are legal requirements for exporting to the EU and UK. Confirm your target market first, then ask the supplier for the matching test reports and their validity dates. For a real-world application example, see Nylon Corrugated Tubing Applied in Automation Control Panels.

Not Sure Which Grade or Size to Specify? Let Our Engineers Help.

Share your application requirements and certification needs — we'll recommend the right product and arrange samples.